Concentric or eccentric service loads on a rectangular spread footing, or a continuous wall footing designed per 1-ft strip. Bottom reinforcement only.
Isolated: 24 to 240 in. Wall: 12 to 120 in.
Isolated footings only. 24 to 240 in; must exceed the column dimension.
Overall thickness. Range 12 to 60 in. Effective depth is computed from this, the cover and the bar size.
Cast against earth: 3 in minimum (Table 20.5.1.3.1). Range 3 to 6 in.
Gross allowable bearing pressure from the geotechnical report. Range 1 to 20 ksf.
Backfill above the footing. Range 90 to 150 pcf.
Soil overburden and self-weight are deducted from qa to get the net allowable pressure. Range 0 to 10 ft.
col_shape
Sets the punching shear location factor and the critical perimeter.
Range 8 to 48 in.
Converted to an equivalent square column per §13.2.7.3. Range 8 to 48 in.
Which footing edge the column is near. Required for edge and corner columns.
Must be less than the footing width B. Range 6 to 24 in.
Specified concrete strength. Range 3,000 to 10,000 psi.
Range 40 to 100 ksi.
1.0 for normal weight concrete; 0.75 to 0.85 for lightweight (Table 19.2.4.2). Range 0.75 to 1.0.
Same bar size in both directions, #4 through #11.
Epoxy coating increases the development length (ψe).
Enter factored loads from your ACI 318-19 load combinations. These drive the flexure, shear, punching, development and interface checks. Footing self-weight is not included in factored loads.
Generate factored loads from service loads on the load combination page.
Must be greater than 0. Maximum 2,000 kip.
Optional; blank is treated as 0. Any moment above 0 means punching shear is reported as not checked.
Optional; blank is treated as 0.
Per foot of wall. Must be greater than 0. Maximum 100 kip/ft.
Optional; per foot of wall. Blank is treated as 0.
Unfactored loads for the soil bearing, kern, overturning and sliding checks (§13.2.1). Do not include footing self-weight or soil above the footing; they are added from the geometry above.
Must be greater than 0. Maximum 1,500 kip.
Optional; used for overturning and sliding.
Per foot of wall. Must be greater than 0. Maximum 75 kip/ft.
Optional; per foot of wall. Used for overturning and sliding.
Sliding resistance is friction only (passive pressure neglected). Range 0.2 to 0.6.